The voltage setting of the computer system and the power cables has to be correct. For further information please contact your local service representative or refer to the ChemStation CD-ROM2 under Support/Printer.
AGILENT CHEMSTATION SOFTWARE PC
Hard-disk with at least 40 GB free capacityġ280x1024 recommended resolution or better graphics adapter and monitor, True ColorsĨ2350A/B GPIB card available with one free IRQ on the PC and one free PCI slot or 82357A/B USB-GPIB Interface **.Īvailable LAN interface with TCP/IP protocol installed and a LAN card (J4100A JetDirect card, G1369A LAN card or equivalent) for the instrument, if needed.Ī printer supported by the current version of the ChemStation. Pentium IV processor operating at 1.5 MHz or higherĪt least 512 MB of RAM for - 2D instrument configuration - 3D instrument configuration - LC/MS instrument configuration - instrument configuration with ChemStore C/S Microsoft Windows compatible pointing device Japanese for Japanese OS/ Japanese ChemStationĪll PC hardware needs to be listed respectively in the Windows XP Professional Hardware Compatibility List (see ) Chinese for Chinese OS/ Chinese ChemStation c. English-US for English and Non- English OS / English ChemStation b. Verify that the regional settings are set correctly a.
AGILENT CHEMSTATION SOFTWARE DRIVER
TEMP=C:\TEMP)Ĭheck if a printer driver is installed on the system TEMP variable points to an existing directory (e.g. Operating System (OS): Windows XP Professional SP2* English/Chinese/JapaneseĪdministrator logon required to the ChemStation PC
AGILENT CHEMSTATION SOFTWARE SOFTWARE
Procedure Checklist: Software Requirements
AGILENT CHEMSTATION SOFTWARE UPGRADE
Additional Information For detailed steps to perform an upgrade installation refer to the Upgrade Preparation Guide for Rev. Users of the instrument should be present throughout the installation and familiarization otherwise important operational, maintenance and safety information may be missed. Assistance with user specific applications may be provided but should be contracted separately. Important Information If you have problems in providing any of the following, please contact your local Agilent office for assistance. Installation sites should be prepared in accordance with the following specifications. Customer Responsibilities Customers should ensure that all necessary operating supplies, consumables and usage dependent items such as columns, vials, syringes and solvents required for the successful installation of instruments and systems are available. To assure that the upgrade of Agilent instruments and systems can be completed successfully by careful preparation and evaluation of the installation site and by ensuring the availability of appropriate utilities, consumables and supplies. Issued: March 2008 Rev 1.0 Copyright 2008 Agilent Technologies WAD Product Support of 4 Has anyone else encountered this problem? We'd be very grateful if anyone knows a way round it.Agilent ChemStation Software Modules G2070BA/G2071BA/G2072BA/G2073BA/G2170BA/G2171BA/G2171BA/G2180BA/G2090BA/ G2710BA/G1601BA/G2201BA I'm scared that the developers of XCMS and Chemstation may be at cross-purposes in their understanding of cdf format, and we'll get caught up between two groups of people declaring the other to be at fault, or they'll both tell me (politely) I'm too stupid to use XCMS, which is quite possibly true. XCMS in R for windows will open cdf files generated on other instruments. Secondly, once we've done this, XCMS crashes when we open the Agilent cdf files ("The R for windows GUI has encountered a problem and has to close"). Firstly, it can only convert files with 8 or less letters in their name, although the newer versions of Chemstation, when using prefix+number file naming, will only produce filenames with 9 or more letters, so we have to change all the file names before the converter will work. Agilent's built-in converter is giving us nightmares. We'd like to use XCMS to process data, running in R for Windows.

We use Agilent's Chemstation (LC-MS) and are currently on version B-03-01 SR1.